Vermont Casting Indoor Fireplace 33LDVT User Manual

FIREPLACE & CHIMNEY COMPONENT SPECIFICATIONS  
PERFECTVIEW 33LDVT TOP VENT  
578mm  
908mm  
152mm  
368mm  
356mm  
851mm  
806mm  
733mm  
753mm  
794mm  
838mm  
466mm  
51mm  
118mm  
86mm  
162mm  
162mm  
225mm  
118mm  
VENT SECTIONS and OFFSETTING ELBOWS  
64"  
1626mm  
48"  
1219mm  
36"  
914mm  
7"  
178mm  
35"  
889mm  
18"  
457mm  
24"  
610mm  
12"  
305mm  
12"  
305mm  
8"  
203mm  
7TDVP24  
7TDVP36  
7TDVP48  
7TDVP8  
7TDVP1218  
7TDVP3564  
7TDVP12  
NOTE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS 11/2” LESS THAN ITS TOTAL  
LENGTH, EXCEPT FOR THE LAST SECTION INSTALLED.  
 
CONTEMPORARY TERMINATIONS  
FIREPLACE FACTS  
9³⁄₄"  
PerfectView 33LDVT  
33” PerfectView Direct Vent Gas Appliance  
32"  
813mm  
FEATURES:  
12¹³⁄₁₆"  
7"  
• 33 PerfectView Direct Vent Gas Appliance  
• 11,200 to 16,000 BTU/hr. input  
• Patented Insta-Flame TM Ceramic Burner System with 4-piece  
Split Oak Ceramic Fiber Log Set  
• Tempered Glass Panel Assembly  
• Adjustable Flame and Heat Output  
• Wall Switch  
7TDVRVT  
7TRVT  
5"  
165  
127mm  
61/2"  
16"  
19"  
mm  
406mm  
13³⁄₁₆"  
• 18 Flex Connector with Shutoff and EB1 electrical box installed  
• Wall Firestop, Zero Clearance Sleeve (Rear vent models only)  
• Rated as Fireplace Heater (AFUE)  
• Uses 4/7Majestic (Direct Vent) Venting Components.  
482mm  
9¹⁄₂"  
7TDVSKS  
BURNER SYSTEM:  
• Capacity  
– Natural:  
– Propane:  
• Fuel - Natural or Propane Gas  
16,000 BTU/HR Max.  
11,200 BTU/HR Min.  
16,000 BTU/HR Max.  
12,000 BTU/HR Min.  
7"  
7TDVSKV  
• Ignition System - Standing Pilot With Piezo Ignitor, A Low Voltage,  
Self-Generating Power Pile System (mV)  
– No Outside Electrical Power Needed OR  
ELBOWS  
– Electronic ignition that requires 120 VAC Electrical hook up  
• Gas Supply Line - Consult Gas Code Book for Correct Sizing  
• Gas Inlet and Manifold Pressures  
7"  
OFFSET w/2-90°  
178mm  
Back to Back  
91/4"  
Natural  
5.5” w.c.  
14” w.c.  
3.5” w.c.  
Propane  
11.0” w.c.  
14.0” w.c.  
10.0” w.c.  
335mm  
17  
"
Minimum Inlet Pressure  
Maximum Inlet Pressure  
Manifold Pressure  
OFFSET  
71/4"  
184mm  
90°  
91/4"  
13"  
330mm  
235mm  
13"  
MINIMUM FLOOR AREA:  
330mm  
• 33” W X 14” D  
235mm  
91/4"  
71/4"  
184mm  
HEARTH EXTENSION:  
A Hearth Extension Is Recommended But Not Required  
90°  
13"  
330mm  
ACCESSORIES:  
33LDVTCR - 33” LDV Ceramic Refractory - Top  
FP889  
FK12  
FK24  
IMTFK  
- Fan and Cord (160cfm) (for RN/RP only)  
- Variable Speed Heat-Activated Fan Kit  
- IMT Thermostat w/ Face Kit  
7TDVRT90  
45°  
OFFSET w/2-45°  
Back to Back  
73/8"  
Minimum Mantel Clearances  
45°  
Clearance From Top  
of Combustion Chamber Opening  
To Bottom of Mantel  
Mantel Depth  
188mm  
45°  
8
1/2”  
2”  
4”  
6”  
8”  
10”  
10 1/2”  
12 1/2”  
14 1/2”  
16 1/2”  
11"  
73/8"  
188mm  
73/8"  
188mm  
The Fireplace Facts Information Sheets are for  
quick reference only and are subject to change with-  
out notice. Actual fireplace instructions must abide  
by specifications provided with each product.  
7TDV45  
FP890  
REV. 10/07  
 

Targus Mouse PAUM01U User Manual
Technika Clothes Dryer T50DM User Manual
Toshiba Remote Starter ME00070B User Manual
TV Ears Microphone Microphone Voice Cord Extender Cord User Manual
Tyco Electronics Portable Radio M7300 Series User Manual
Vax Vacuum Cleaner C91 P2 User Manual
Vermont Casting Electric Heater 4030 4036 User Manual
Viking Microwave Oven RDMOR206 User Manual
VTech Cordless Telephone DS6321 2 User Manual
VTech Cordless Telephone USB7200 User Manual