Vector Power Supply VEC022 User Manual

VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 1  
VEC022  
Jump-Start System  
12 VOLT DC POWER SUPPLY  
IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR  
PURCHASE CALL TOLL FREE 866-584-5504. IN MOST  
CASES A SERVICE REPRESENTATIVE CAN RESOLVE  
YOUR PROBLEM OVER THE PHONE.  
KEY INFORMATION YOU SHOULD  
KNOW:  
• Jump-start any engine system  
with a standard 12 volt DC  
battery  
• Easy-to-read series of LED  
charge indicators  
• Jump-Start System can be  
recharged from any standard  
110/120 volt AC power  
source  
• Built-in Emergency Area Light  
BEFORE RETURNING THIS PRODUCT FOR ANY REASON,  
PLEASE CALL TOLL FREE 866-584-5504  
OWNER’S MANUAL AND  
WARRANTY INFORMATION  
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,  
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. READ  
CAREFULLY BEFORE USE, AND RETAIN FOR FUTURE REFERENCE.  
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312  
Toll Free: 866-584-5504  
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 3  
SAFETY INFORMATION  
WARNING: Warning statements identify conditions or practices that may result in  
personal injury or loss of life  
1. When working with lead acid batteries, always make sure immediate  
assistance is available in case of accident or emergency.  
2. Always use protective eyewear when using this product: contact with battery  
acid may cause blindness and/or severe burns, be aware of first aid  
procedures in case of accidental contact with battery acid.  
3. There is a risk of explosive gases being released when lead acid batteries  
are being charged or discharged. Failure to follow instructions may cause  
property damage, explosive hazard, and/or personal injury.  
4. When connecting the battery clamps to a discharged battery, and an alarm  
sounds - the polarity is reversed.  
5. When charging unit from a 110/120 volt AC electrical outlet in any wet or  
damp area, make sure that the outlet used is protected by a ground fault  
interrupt (GFI) Switch.  
6. When charging the unit near water, do not allow the electrical cords and  
outlets to get wet or come near water–electrical shock could result.  
7. Jump-start procedures should only be performed in a safe, dry, well-  
ventilated area.  
8. Always store battery clamps on clamp tabs when not in use. Never touch  
battery clamps together, this can cause dangerous sparks, power arcing  
and/or explosion.  
9. When using this unit in proximity to the vehicle’s battery and engine, stand  
the unit on a flat, stable surface, and be sure to keep all clamps, cords,  
clothing and body parts away from moving vehicle components.  
10. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause  
dangerous static-electricity sparks. Remove all jewelry or metal objects that  
could cause short circuits or react with battery acid.  
11. Always disconnect the negative (Black) jumper cable first: followed by the  
positive (Red) jumper cable, except for positive ground systems.  
12. Never allow red and black clamps to touch each other or another common  
metal conductor–this could cause damage to the unit and/or create  
sparking/explosion hazard. Always store battery clamps on built-in clamp tabs  
when not in use.  
13. Do not expose battery to fire or intense heat as it may explode. Before  
disposing of the battery, protect exposed terminals with heavy-duty electrical  
tape to prevent shorting (shorting can result in injury or fire).  
14. Do not smoke or use inflammable items (matches, cigarette lighters, etc.)  
while working on a vehicles battery system.  
15. Keep unit out of reach of children (whether stored, or in use)!  
FIRST AID: SKIN: If battery acid comes in contact with skin, rinse immediately  
with water, then wash thoroughly with soap and water. If redness,  
pain, or irritation occurs, seek immediate medical attention.  
EYES: If battery acid comes in contact with eyes, flush eyes  
immediately, for a minimum of 15 minutes and seek immediate  
medical attention.  
3
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 4  
CAUTION: Caution statements advise against certain conditions and practices  
that may result in damage to vehicles, appliances and/or the Jump-  
Starter.  
IMPORTANT:  
Although this unit is delivered in a partially charged state, you must fully charge it  
with the supplied 110/120 volt AC charger for a full 48 hours before using it for  
the first time. You cannot overcharge the unit using the AC charger method.  
1. Use only the supplied cords/adapters for recharging this unit. Do not recharge  
for more than 3-4 hours maximum using 12 volt DC method. Recharge unit  
after each use.  
2. All On/Off switches should be in the OFF position when the unit is charging  
or not in use. Make sure all switches are in the OFF position before connection  
to a power source or load.  
3. Never insert anything other than the supplied power/recharging cords or  
recommended appliance power/recharging cords into the 12 volt DC  
charging/power outlet on this unit. Do not use any accessory that is not  
recommended or provided by the manufacturer.  
4. Do not use this unit to operate appliances that draw more than 5 amps.  
5. This system is designed to be used only on vehicles with 12 volt DC battery  
systems. Do not connect to a 6 volt or 24 volt battery system.  
6. This system is not designed to be used as a replacement for a vehicular battery.  
Do not attempt to operate a vehicle that does not have a battery installed.  
7. Vehicles that have on-board computerized systems may be damaged if vehicle  
battery is jump-started. Before jump-starting, read the vehicles owners  
manual to confirm that external-starting assistance is advised.  
8. Excessive engine cranking can damage a vehicle’s starter motor. If the engine  
fails to start after the recommended number of attempts, discontinue jump-start  
procedures and look for other problems that may need to be corrected.  
9. Although this unit contains a non-spillable battery, it is recommended that unit  
be kept upright during storage, use and recharging. To avoid possible damage  
that may shorten the units working life, protect it from direct sunlight, direct  
heat and/or moisture.  
10. Check unit periodically for wear and tear. Replace worn or defective parts  
immediately. Contact Vector Customer Service department toll-free  
866-584-5504.  
11. Do not attempt to jump-start a frozen battery.  
12. Never submerge this unit in water.  
4
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 5  
1. INTRODUCTION  
Congratulations on selecting the VECTOR® JUMP-STARTER, and 12 VOLT DC  
POWER SUPPLY. This compact jump-starter is unique in the amount of energy  
it can supply for its size. The internal battery is a high density sealed, lead-acid  
battery that stores and delivers energy comparable to full sized ordinary jump-  
starters. Please read this guide carefully before use to ensure optimum  
performance and avoid damage to the unit or items that you are using it with.  
The VECTOR® JUMP-STARTER & 12 VOLT DC POWER SUPPLY is a compact,  
durable and portable jump-start system for vehicles and boats that have a  
standard 12 volt battery system. This self-contained, rechargeable system will  
start most vehicles and boats without the need for a host vehicle or 110/120  
volt AC power supply. It can also be used as a safe, portable source of 12  
volt DC electric power in remote locations and/or emergency situations. It is  
ideal for use with Vector 12 volt DC cordless, portable, rechargeable  
products and MAXXSST DC/AC Power Inverters.  
Use the VECTOR JUMP-START SYSTEM to:  
• Jump-start any engine system with a standard 12 volt DC battery: boat;  
truck; car; airplane; RV; personal watercraft; snowmobile; garden tractor;  
gasoline engine generator, etc.  
• Operate: 12 volt DC fans, fluorescent worklights, cellular phones (can quick-  
charge a cellular phone by using the phone’s 12 volt DC adapter cord),  
spotlights, TVs, portable radios, cassette or CD players, and more. Operate:  
Certain 110/120 volt AC accessories (requires a Vector 12 volt power  
inverter, sold separately).  
The JUMP-START SYSTEM has an easy-to-read series of LED (Light Emitting  
Diode) charge indicators that show the level of charge in the battery. Charge  
level can be viewed when the Battery Level Status pushbutton is pressed. A 12  
volt DC accessory outlet is provided for use with appliances that can operate  
from a vehicle 12VDC accessory outlet. This allows maximum portability and  
utility when the Jump-Start System is used in remote locations.  
The Jump-Start System can be recharged from any standard 110/120 volt AC  
power source using the supplied AC Recharge Adapter. The adapter barrel  
connector attaches to the Recharge Port on the front right of the jump-starter.  
A built-in 12 volt DC appliance outlet and the appropriate DC/DC  
charging/adapter cord is used to recharge the battery from another 12 volt DC  
source. When pressed, the Battery Level Status pushbutton will show the battery  
level status (from LOW to HIGH). The green LED (HIGH) indicator illuminates  
when the unit is fully charged and recharging can be discontinued. An  
ON/OFF pushbutton operates the built-in work/emergency light.  
5
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 6  
5
4
1
1
2
3
FIGURE 1A (FRONT VIEW)  
FIGURE 1B (REAR VIEW)  
1. 12 Volt DC Outlets  
2. AC Recharge Adapter Barrel Connector Receptacle  
3. Built-in LED Emergency/Area light  
4. Negative (-) Black Clamp  
5. Positive (+) Red Clamp  
6. LED Indicators  
7. Area light ON/OFF Pushbutton  
8. ON/OFF Safety Power Switch  
9. Battery Level Status Pushbutton  
6
7
8
9
6
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 7  
ADDITIONAL FEATURES:  
• Includes non-spillable, maintenance-free, heavy-duty, sealed battery  
• Sturdy and unique compact design provides completely portable 12 volt DC  
power  
• Safe to use, transport, and store  
• Requires no maintenance (other than recharging) for optimum operation  
• Automatic taper charge for AC recharge  
• Molded high-impact case is tough and durable  
• Built-in emergency/area light for roadside repairs and use in remote  
locations without utility power  
2. SAFETY WARNINGS  
1. Before using this system to jump-start any vehicle or boat, read and understand  
all instructions, safety tips, warnings, cautions and first aid information  
provided in this manual and on the product labeling. Additional important  
information may also be provided by the vehicles battery system manufacturer.  
2. Be aware of first aid procedures before attempting jump-start procedure.  
3. Always wear protective eyewear when working with a lead acid-type battery.  
4. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while  
working on a vehicles battery system.  
5. When using this jump-starter in proximity to the vehicles battery and engine,  
stand the unit on a flat, stable surface, and be sure to keep all cords and cables  
away from any moving parts.  
6. Check unit periodically for wear and tear. Replace worn or defective parts  
immediately; contact Vector Customer Service Department toll-free: 866-584-  
7. Do not attempt to jump-start a frozen battery.  
8. NEVER submerge this unit in water.  
9. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause  
dangerous static electricity sparks. Remove all jewelry or metal objects-they can  
cause short circuits or react with battery acid to cause severe burns. Remove or  
secure any loose clothing, and restrain long hair, before attempting jump-start  
procedure.  
10. Lead-acid batteries generate hydrogen gas during normal operation. More gas  
is generated when the battery is charging. Hydrogen gas is explosive,  
poisonous to breathe and highly flammable.  
Recommendations for optimum performance of the VECTOR® Jump-Starter:  
CAUTION:  
1. To avoid possible damage that may shorten the units working life, protect this  
unit from direct sunlight, direct heat and moisture.  
2. This system is to be used ONLY on vehicles, boats, garden tractors and  
gasoline powered generators with 12 volt DC battery systems.  
NOTE: A marine (boat) battery must be removed and charged on shore. To charge  
it on board requires equipment specially designed for marine use.  
7
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 8  
3. This system is NOT designed to be installed as a replacement for a vehicle battery.  
4. Vehicles that have on-board computerized systems may be damaged if vehicle  
battery is jump-started. Before jump-starting this type of vehicle, read the  
vehicle owners manual to confirm that external-starting assistance is advised.  
5. Excessive engine cranking can damage the vehicles starter motor. If the engine  
fails to start after the recommended number of attempts, discontinue jump-start  
procedure and look for other problems that may need to be corrected.  
6. This VECTOR® jump-starter is equipped with a manual ON/OFF switch. Once  
the connections are properly made, turn the switch ON and you are ready to  
jump-start the vehicle.  
2.1 JUMP-STARTING INSTRUCTIONS  
This jump-starter is equipped with an manual safety switch that only allows  
jump-start energy to flow when proper connections are made to battery and  
frame.  
Connect – Red clamp first, then black clamp.  
Disconnect – Black clamp first, then red clamp.  
1. Make sure jump-start systems ON/OFF power switch is turned to OFF  
2. Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell  
phone, etc.). Place vehicle in “park” and set the emergency brake.  
3. Remove jumper clamps from clamp tabs.  
4. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM  
NEGATIVE BATTERY TERMINAL IS CONNECTED TO CHASSIS, (MOST  
COMMON)  
4a. Connect positive (+) red clamp to vehicle batterys positive terminal.  
4b. Connect negative (-) black clamp to chassis or a solid, non-moving,  
metal vehicle component or body part. Never clamp directly to  
negative battery terminal or moving part.  
5. Procedure for jump-starting POSITIVE GROUND SYSTEMS (NOTE: In the  
rare event that the vehicle to be started has a Positive Grounded System  
(positive battery terminal is connected to chassis) replace steps 3a and  
3b above with steps 4a and 4b, then proceed to steps 6 through 8  
below.  
5a. Connect negative (-) black clamp to vehicle batterys negative terminal  
5b. Connect positive (+) red clamp to vehicle chassis or a solid, non-  
moving, metal vehicle component or body part. DO NOT CLAMP  
DIRECTLY TO POSITIVE BATTERY TERMINAL OR MOVING PART.  
6. Be sure jump-starters positive and negative clamps are properly  
connected to battery.  
7. Turn jump-starter safety switch to ON.  
8. Start vehicle (do not turn key for longer than 5-6 seconds).  
9. After vehicle starts, remove clamps (disconnect the frame or engine  
clamp first, followed by the battery cable) and replace them on the built-  
in clamp tabs. Squeeze the handles and slide the clamp into position  
and release your grip.  
8
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 9  
CAUTION:  
If engine fails to start, leave ignition key turned off and disconnect the negative  
(-) clamp first, then the positive (+) clamp. Try again later – the engine may be  
flooded.  
• Recharge jump-start system after each use.  
WARNING:  
• Always disconnect the engine or frame jumper clamp first; followed by the  
battery jumper clamp  
• Never allow red and black clamps to touch each other or another common  
metal conductor; this could cause damage to the unit and/or create  
sparking/explosion hazard  
• There is a risk of explosive gases being released when batteries are charged  
or discharged. Failure to follow instructions may cause property damage,  
explosive hazard, and/or personal injury  
• Always use protective eyewear when using this product: contact with battery  
acid may cause blindness and/or severe burns  
• Keep out of childrens reach  
• ALWAYS store battery clamps on clamp tabs when not in use. Never touch  
battery clamps together, this can cause dangerous sparks, power arcing  
and/or explosion  
FIRST AID:  
• SKIN: If battery acid comes in contact with skin, rinse immediately with  
water, then wash thoroughly with soap and water. If redness, pain, or  
irritation occurs, seek immediate medical attention  
• EYES: If battery acid comes in contact with eyes, flush eyes immediately for  
a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION  
3. CHARGING/RECHARGING  
For maximum battery life, we recommend the VECTOR® system be kept fully  
charged at all times. If the battery is allowed to remain in a discharged state,  
battery life will be shortened.  
NOTE: Recharging battery after each use will prolong battery life; frequent  
discharges between recharges will reduce battery life  
IMPORTANT:  
• MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING  
• Charge unit for full 48 hours using AC method, prior to first use  
• Recharge unit fully after each use  
• Recharge unit once a month when not in use  
9
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 10  
3.1 110/120 VOLT AC CHARGING  
1. Plug the barrel connector end of the AC/DC adapter into the small barrel  
receptacle port on the jump-starter.  
2. Plug the AC/DC adapter/charger into any standard 110/120 volt AC  
wall outlet.  
3. After initial 48 hour charge, charge this device for at least 24-30 hours or until  
the green FULL indicator lights. Charge at least once a month when not in use.  
4. When charging is complete and the FULL light lights, remove the AC/DC  
charger plug and store in a safe place.  
NOTE: The unit cannot be overcharged using the AC method. The VECTOR®  
system also comes with a DC/DC charging adapter for recharging the  
unit from a 12 volt DC accessory outlet in a vehicle or boat.  
12 volt DC to DC method will NOT recharge the unit as effectively as  
recharging from a 110/120 volt AC outlet. The 12 volt DC recharging  
procedure is recommended only when it is necessary, as continued use of the  
12 volt DC recharging procedure may shorten the battery systems life.  
If unit is fully discharged, it is recommended that the vehicle being used for  
recharging be left running while the unit is being charged using the 12 volt DC  
method.  
WARNING:  
Do not recharge for more than 3-4 hours maximum using 12 volt DC method.  
3.2 12 VOLT DC CHARGING  
1. Insert the plug that is marked “TO VEHICLE ACCESSORY OUTLET” of the  
DC/DC charging adapter into the 12 volt DC accessory receptacle on the  
vehicle or boat.  
2. Insert the plug at the other end of this charging adapter marked “TO JUMP  
STARTER OUTLET” into the recharging port on the front panel of the unit.  
3. IN ORDER TO PROPERLY CHECK THE CHARGE LEVEL OF THE JUMP  
STARTER BATTERY DURING DC CHARGING, DISCONNECT DC  
ADAPTER FROM ACCESSORY OUTLET, PUSH BATTERY LEVEL STATUS  
SWITCH AND OBSERVE CHARGE LEVEL. UNIT IS CHARGED WHEN  
GREEN LED LIGHTS. DO NOT EXCEED 3-4 HOURS MAXIMUM.  
3. When charging is completed, remove the power cord and store in a safe  
place.  
CAUTION: THIS PLUG USES AN 8 AMP FUSE. FOR CONTINUED  
PROTECTION AGAINST RISK OF FIRE, REPLACE FUSE ONLY WITH  
SAME TYPE AND RATING.  
3.3 REPLACE FUSE  
1. Remove plug from accessory outlet. Remove the gold cap by turning  
counterclockwise and lifting off.  
2. Remove center pin and spring.  
3. Replace fuse with same type and size fuse (8 amp).  
4. Replace center pin and spring inside plug.  
5. Replace gold cap by turning clockwise onto plug.  
10  
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 11  
3.4 ESTIMATED BATTERY LIFE  
Table I shows the relationship of the frequency of use between recharging and  
the expected number of discharge/recharge cycles.  
Table I - Estimated Battery Life between recharges (lifetime of units battery)  
USE  
RECHARGES  
1000+  
700+  
1
5
10  
500+  
4. OPERATION AS A 12 VOLT DC PORTABLE POWER SUPPLY  
1. Lift up the cover of the units 12 volt DC accessory receptacle (See Figure 1).  
2. Insert the 12 volt DC plug from the appliance into the receptacle on the unit.  
3. Turn on the appliance, and operate as usual.  
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT  
DRAW MORE THAN 5 AMPS DC  
Table II shows the estimated 12 volt DC operation time when using a fully  
charged system.  
Table II - VECTOR® as a 12 volt DC Power Supply  
Appliance  
Estimated Power Usage Operating Time  
(Watts)  
(hours)  
Cell phone  
1
120 (talk time)  
Fluorescent light  
4
40  
24  
14  
10  
2
Radio, fan, depth finder  
Camcorder, VCR, spotlight  
Power tools, bilge pump  
Car vacuum  
9
15  
24  
80  
NOTE: ALL TIMES ARE APPROXIMATE AND BASED UPON A FULLY CHARGED UNIT.  
5. EMERGENCY AREA LIGHT  
The area light is controlled by an On/Off pushbutton. Make sure the lamp is turned  
OFF when the unit is being recharged or stored. The light is efficient and will  
operate up to 200 hours on a full charge. The area light’s operating life is 10,000  
hours.  
6. REPLACEMENT PARTS  
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer  
Service: 954-584-4446 or toll-free 866-584-5504.  
6.1 BATTERY REPLACEMENT  
It is recommended that the unit be returned to Vector Customer Service for  
battery replacement: Contact 954-584-4446 or toll-free 866-584-5504.  
WARNING:  
• Do not dispose of the battery in fire as this may result in an explosion  
• Before disposing of the battery, protect exposed terminals with heavy-duty  
electrical tape to prevent shorting (shorting can result in injury or fire)  
• Do not expose battery to fire or intense heat as it may explode  
11  
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 12  
6.2 BATTERY DISPOSAL:  
This unit contains a maintenance-free, non-spillable, sealed lead-  
acid battery. This battery is fully recyclable and should be accepted  
at any location that accepts common automotive starter batteries.  
Examples of places that accept these batteries are: County or  
municipal recycling drop-off centers, scrap metal dealers and  
retailers who sell automotive replacement lead acid starter  
batteries. For more information on recycling this battery, call toll-  
free 877-288-7722.  
7. SPECIFICATIONS  
Model ..............................................................................VEC022  
Boost Ampere ............................450 Instantaneous Cranking Amps  
Battery Type ..............Sealed, high energy density, AGM, lead-acid,  
........rechargeable, maintenance-free, 12 volt DC, 19 Amp-hour  
Area Light ..............................................Light Emitting Diode (LED)  
Booster Cables ..............................................Heavy duty cable with  
..........................................................450 Amp copper clamps  
Accessory Socket ............................Self-Resetting Breaker 5 Amps  
DC Charging Adapter ....................................................12 volt DC  
AC Charging Adapter 110/120 Volt AC (700mA, 12 Volt DC Output)  
12  
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 13  
2-YEAR LIMITED WARRANTY  
This limited warranty program is the only one that applies to this product, and it sets forth all the  
responsibilities of Vector Products, Inc., regarding this product. There is no other warranty, other than  
those described herein.  
This Vector Products, Inc. product is warranted, to the original purchaser only, to be free of defects in  
materials and workmanship for two years from the date of purchase without additional charge. The  
warranty does not extend to subsequent purchasers or users. Vector Products, Inc. will not be responsible  
for any amount of damage in excess of the retail purchase price of the product under any circumstances.  
Incidental and consequential damages are specifically excluded from coverage under this warranty.  
This product is not intended for commercial use. This warranty does not apply to accessories or damage  
to units from misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity  
power sources.  
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage  
prepaid to Vector Products, Inc.. Any defective product, other than accessories, that is returned to Vector  
Products, Inc. within 30 days of the date of purchase will be replaced free of charge. If such a product  
is returned more than 30 days but less than two years from the purchase date, Vector Products, Inc. will  
repair the unit or, at its option, replace it free of charge.  
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector Products, Inc.s  
option. A unit may be replaced with a new or reconditioned unit of the same or comparable design.  
The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty  
period. The customer is responsible for the shipping charges on all returned items after 30 days. During  
the warranty period, Vector Products, Inc. will be responsible for the return shipping charges.  
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from  
normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or  
exposure to sunlight), accidents, damage during shipping to our service facility, alterations,  
unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and  
maintenance, fire, flood and Acts of God.  
If your problem is not covered by this warranty, call our Technical Support Department toll free  
866-584-5504 for general repair information and charges if applicable. You may also contact us  
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations  
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential  
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser  
specific legal rights; other rights, which vary from state to state, may apply.  
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Products, Inc. Technical  
Support by telephone, fax or mail. We suggest that you keep the original packaging in case you need  
to ship the unit. When returning a product, include your name, address, phone number, dated sales  
receipt (or copy) and a description of the reason for return and product serial number. After repairing  
or replacing the unit, we will make every effort to return it to you within four weeks.  
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Products, Inc..  
Enter “VEC022” as Model and “Jump-Start System and 12VDC Power Supply” as Product Type. All  
Vector Products, Inc. products must be registered within (30) days of purchase to activate this warranty.  
Mail the completed registration form, along with a copy of the original sales receipt to:  
ATTN.: CUSTOMER SERVICE / VECTOR PRODUCTS, INC.  
4140 S.W. 30Ave., Ft. Lauderdale, FL 33312  
TEL: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.  
13  
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 14  
14  
 
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 15  
DS073106  
 

Tektronix Stereo System WFM90 User Manual
Toastmaster Electric Heater E17UAC INS 20 User Manual
Toshiba DVD Recorder SD C2732 User Manual
Toshiba Flat Panel Television 20HL85 User Manual
Toshiba Power Supply G3 Plus Pack User Manual
Tyco Battery Charger 96V User Manual
Uniden Marine Radio MC 610 User Manual
United States Stove Electric Heater A9740L User Manual
VIPowER MP3 Docking Station VP 8059 User Manual
Vulcan Hart TV Mount E 23 C User Manual