VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 1
VEC022
Jump-Start System
12 VOLT DC POWER SUPPLY
IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR
PURCHASE CALL TOLL FREE 866-584-5504. IN MOST
CASES A SERVICE REPRESENTATIVE CAN RESOLVE
YOUR PROBLEM OVER THE PHONE.
KEY INFORMATION YOU SHOULD
KNOW:
• Jump-start any engine system
with a standard 12 volt DC
battery
• Easy-to-read series of LED
charge indicators
• Jump-Start System can be
recharged from any standard
110/120 volt AC power
source
• Built-in Emergency Area Light
BEFORE RETURNING THIS PRODUCT FOR ANY REASON,
PLEASE CALL TOLL FREE 866-584-5504
OWNER’S MANUAL AND
WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,
OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. READ
CAREFULLY BEFORE USE, AND RETAIN FOR FUTURE REFERENCE.
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312
Toll Free: 866-584-5504
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 3
SAFETY INFORMATION
WARNING: Warning statements identify conditions or practices that may result in
personal injury or loss of life
1. When working with lead acid batteries, always make sure immediate
assistance is available in case of accident or emergency.
2. Always use protective eyewear when using this product: contact with battery
acid may cause blindness and/or severe burns, be aware of first aid
procedures in case of accidental contact with battery acid.
3. There is a risk of explosive gases being released when lead acid batteries
are being charged or discharged. Failure to follow instructions may cause
property damage, explosive hazard, and/or personal injury.
4. When connecting the battery clamps to a discharged battery, and an alarm
sounds - the polarity is reversed.
5. When charging unit from a 110/120 volt AC electrical outlet in any wet or
damp area, make sure that the outlet used is protected by a ground fault
interrupt (GFI) Switch.
6. When charging the unit near water, do not allow the electrical cords and
outlets to get wet or come near water–electrical shock could result.
7. Jump-start procedures should only be performed in a safe, dry, well-
ventilated area.
8. Always store battery clamps on clamp tabs when not in use. Never touch
battery clamps together, this can cause dangerous sparks, power arcing
and/or explosion.
9. When using this unit in proximity to the vehicle’s battery and engine, stand
the unit on a flat, stable surface, and be sure to keep all clamps, cords,
clothing and body parts away from moving vehicle components.
10. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause
dangerous static-electricity sparks. Remove all jewelry or metal objects that
could cause short circuits or react with battery acid.
11. Always disconnect the negative (Black) jumper cable first: followed by the
positive (Red) jumper cable, except for positive ground systems.
12. Never allow red and black clamps to touch each other or another common
metal conductor–this could cause damage to the unit and/or create
sparking/explosion hazard. Always store battery clamps on built-in clamp tabs
when not in use.
13. Do not expose battery to fire or intense heat as it may explode. Before
disposing of the battery, protect exposed terminals with heavy-duty electrical
tape to prevent shorting (shorting can result in injury or fire).
14. Do not smoke or use inflammable items (matches, cigarette lighters, etc.)
while working on a vehicle’s battery system.
15. Keep unit out of reach of children (whether stored, or in use)!
FIRST AID: SKIN: If battery acid comes in contact with skin, rinse immediately
with water, then wash thoroughly with soap and water. If redness,
pain, or irritation occurs, seek immediate medical attention.
EYES: If battery acid comes in contact with eyes, flush eyes
immediately, for a minimum of 15 minutes and seek immediate
medical attention.
3
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 4
CAUTION: Caution statements advise against certain conditions and practices
that may result in damage to vehicles, appliances and/or the Jump-
Starter.
IMPORTANT:
Although this unit is delivered in a partially charged state, you must fully charge it
with the supplied 110/120 volt AC charger for a full 48 hours before using it for
the first time. You cannot overcharge the unit using the AC charger method.
1. Use only the supplied cords/adapters for recharging this unit. Do not recharge
for more than 3-4 hours maximum using 12 volt DC method. Recharge unit
after each use.
2. All On/Off switches should be in the OFF position when the unit is charging
or not in use. Make sure all switches are in the OFF position before connection
to a power source or load.
3. Never insert anything other than the supplied power/recharging cords or
recommended appliance power/recharging cords into the 12 volt DC
charging/power outlet on this unit. Do not use any accessory that is not
recommended or provided by the manufacturer.
4. Do not use this unit to operate appliances that draw more than 5 amps.
5. This system is designed to be used only on vehicles with 12 volt DC battery
systems. Do not connect to a 6 volt or 24 volt battery system.
6. This system is not designed to be used as a replacement for a vehicular battery.
Do not attempt to operate a vehicle that does not have a battery installed.
7. Vehicles that have on-board computerized systems may be damaged if vehicle
battery is jump-started. Before jump-starting, read the vehicle’s owners
manual to confirm that external-starting assistance is advised.
8. Excessive engine cranking can damage a vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedures and look for other problems that may need to be corrected.
9. Although this unit contains a non-spillable battery, it is recommended that unit
be kept upright during storage, use and recharging. To avoid possible damage
that may shorten the unit’s working life, protect it from direct sunlight, direct
heat and/or moisture.
10. Check unit periodically for wear and tear. Replace worn or defective parts
immediately. Contact Vector Customer Service department toll-free
866-584-5504.
11. Do not attempt to jump-start a frozen battery.
12. Never submerge this unit in water.
4
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 5
1. INTRODUCTION
Congratulations on selecting the VECTOR® JUMP-STARTER, and 12 VOLT DC
POWER SUPPLY. This compact jump-starter is unique in the amount of energy
it can supply for its size. The internal battery is a high density sealed, lead-acid
battery that stores and delivers energy comparable to full sized ordinary jump-
starters. Please read this guide carefully before use to ensure optimum
performance and avoid damage to the unit or items that you are using it with.
The VECTOR® JUMP-STARTER & 12 VOLT DC POWER SUPPLY is a compact,
durable and portable jump-start system for vehicles and boats that have a
standard 12 volt battery system. This self-contained, rechargeable system will
start most vehicles and boats without the need for a host vehicle or 110/120
volt AC power supply. It can also be used as a safe, portable source of 12
volt DC electric power in remote locations and/or emergency situations. It is
ideal for use with Vector 12 volt DC cordless, portable, rechargeable
products and MAXXSST DC/AC Power Inverters.
Use the VECTOR JUMP-START SYSTEM to:
• Jump-start any engine system with a standard 12 volt DC battery: boat;
truck; car; airplane; RV; personal watercraft; snowmobile; garden tractor;
gasoline engine generator, etc.
• Operate: 12 volt DC fans, fluorescent worklights, cellular phones (can quick-
charge a cellular phone by using the phone’s 12 volt DC adapter cord),
spotlights, TVs, portable radios, cassette or CD players, and more. Operate:
Certain 110/120 volt AC accessories (requires a Vector 12 volt power
inverter, sold separately).
The JUMP-START SYSTEM has an easy-to-read series of LED (Light Emitting
Diode) charge indicators that show the level of charge in the battery. Charge
level can be viewed when the Battery Level Status pushbutton is pressed. A 12
volt DC accessory outlet is provided for use with appliances that can operate
from a vehicle 12VDC accessory outlet. This allows maximum portability and
utility when the Jump-Start System is used in remote locations.
The Jump-Start System can be recharged from any standard 110/120 volt AC
power source using the supplied AC Recharge Adapter. The adapter barrel
connector attaches to the Recharge Port on the front right of the jump-starter.
A built-in 12 volt DC appliance outlet and the appropriate DC/DC
charging/adapter cord is used to recharge the battery from another 12 volt DC
source. When pressed, the Battery Level Status pushbutton will show the battery
level status (from LOW to HIGH). The green LED (HIGH) indicator illuminates
when the unit is fully charged and recharging can be discontinued. An
ON/OFF pushbutton operates the built-in work/emergency light.
5
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 6
5
4
1
1
2
3
FIGURE 1A (FRONT VIEW)
FIGURE 1B (REAR VIEW)
1. 12 Volt DC Outlets
2. AC Recharge Adapter Barrel Connector Receptacle
3. Built-in LED Emergency/Area light
4. Negative (-) Black Clamp
5. Positive (+) Red Clamp
6. LED Indicators
7. Area light ON/OFF Pushbutton
8. ON/OFF Safety Power Switch
9. Battery Level Status Pushbutton
6
7
8
9
6
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 7
ADDITIONAL FEATURES:
• Includes non-spillable, maintenance-free, heavy-duty, sealed battery
• Sturdy and unique compact design provides completely portable 12 volt DC
power
• Safe to use, transport, and store
• Requires no maintenance (other than recharging) for optimum operation
• Automatic taper charge for AC recharge
• Molded high-impact case is tough and durable
• Built-in emergency/area light for roadside repairs and use in remote
locations without utility power
2. SAFETY WARNINGS
1. Before using this system to jump-start any vehicle or boat, read and understand
all instructions, safety tips, warnings, cautions and first aid information
provided in this manual and on the product labeling. Additional important
information may also be provided by the vehicle’s battery system manufacturer.
2. Be aware of first aid procedures before attempting jump-start procedure.
3. Always wear protective eyewear when working with a lead acid-type battery.
4. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while
working on a vehicle’s battery system.
5. When using this jump-starter in proximity to the vehicle’s battery and engine,
stand the unit on a flat, stable surface, and be sure to keep all cords and cables
away from any moving parts.
6. Check unit periodically for wear and tear. Replace worn or defective parts
immediately; contact Vector Customer Service Department toll-free: 866-584-
7. Do not attempt to jump-start a frozen battery.
8. NEVER submerge this unit in water.
9. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause
dangerous static electricity sparks. Remove all jewelry or metal objects-they can
cause short circuits or react with battery acid to cause severe burns. Remove or
secure any loose clothing, and restrain long hair, before attempting jump-start
procedure.
10. Lead-acid batteries generate hydrogen gas during normal operation. More gas
is generated when the battery is charging. Hydrogen gas is explosive,
poisonous to breathe and highly flammable.
Recommendations for optimum performance of the VECTOR® Jump-Starter:
CAUTION:
1. To avoid possible damage that may shorten the unit’s working life, protect this
unit from direct sunlight, direct heat and moisture.
2. This system is to be used ONLY on vehicles, boats, garden tractors and
gasoline powered generators with 12 volt DC battery systems.
NOTE: A marine (boat) battery must be removed and charged on shore. To charge
it on board requires equipment specially designed for marine use.
7
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 8
3. This system is NOT designed to be installed as a replacement for a vehicle battery.
4. Vehicles that have on-board computerized systems may be damaged if vehicle
battery is jump-started. Before jump-starting this type of vehicle, read the
vehicle owner’s manual to confirm that external-starting assistance is advised.
5. Excessive engine cranking can damage the vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedure and look for other problems that may need to be corrected.
6. This VECTOR® jump-starter is equipped with a manual ON/OFF switch. Once
the connections are properly made, turn the switch ON and you are ready to
jump-start the vehicle.
2.1 JUMP-STARTING INSTRUCTIONS
This jump-starter is equipped with an manual safety switch that only allows
jump-start energy to flow when proper connections are made to battery and
frame.
Connect – Red clamp first, then black clamp.
Disconnect – Black clamp first, then red clamp.
1. Make sure jump-start system’s ON/OFF power switch is turned to OFF
2. Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell
phone, etc.). Place vehicle in “park” and set the emergency brake.
3. Remove jumper clamps from clamp tabs.
4. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM
NEGATIVE BATTERY TERMINAL IS CONNECTED TO CHASSIS, (MOST
COMMON)
4a. Connect positive (+) red clamp to vehicle battery’s positive terminal.
4b. Connect negative (-) black clamp to chassis or a solid, non-moving,
metal vehicle component or body part. Never clamp directly to
negative battery terminal or moving part.
5. Procedure for jump-starting POSITIVE GROUND SYSTEMS (NOTE: In the
rare event that the vehicle to be started has a Positive Grounded System
(positive battery terminal is connected to chassis) replace steps 3a and
3b above with steps 4a and 4b, then proceed to steps 6 through 8
below.
5a. Connect negative (-) black clamp to vehicle battery’s negative terminal
5b. Connect positive (+) red clamp to vehicle chassis or a solid, non-
moving, metal vehicle component or body part. DO NOT CLAMP
DIRECTLY TO POSITIVE BATTERY TERMINAL OR MOVING PART.
6. Be sure jump-starter’s positive and negative clamps are properly
connected to battery.
7. Turn jump-starter safety switch to ON.
8. Start vehicle (do not turn key for longer than 5-6 seconds).
9. After vehicle starts, remove clamps (disconnect the frame or engine
clamp first, followed by the battery cable) and replace them on the built-
in clamp tabs. Squeeze the handles and slide the clamp into position
and release your grip.
8
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 9
CAUTION:
•
If engine fails to start, leave ignition key turned off and disconnect the negative
(-) clamp first, then the positive (+) clamp. Try again later – the engine may be
flooded.
• Recharge jump-start system after each use.
WARNING:
• Always disconnect the engine or frame jumper clamp first; followed by the
battery jumper clamp
• Never allow red and black clamps to touch each other or another common
metal conductor; this could cause damage to the unit and/or create
sparking/explosion hazard
• There is a risk of explosive gases being released when batteries are charged
or discharged. Failure to follow instructions may cause property damage,
explosive hazard, and/or personal injury
• Always use protective eyewear when using this product: contact with battery
acid may cause blindness and/or severe burns
• Keep out of children’s reach
• ALWAYS store battery clamps on clamp tabs when not in use. Never touch
battery clamps together, this can cause dangerous sparks, power arcing
and/or explosion
FIRST AID:
• SKIN: If battery acid comes in contact with skin, rinse immediately with
water, then wash thoroughly with soap and water. If redness, pain, or
irritation occurs, seek immediate medical attention
• EYES: If battery acid comes in contact with eyes, flush eyes immediately for
a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION
3. CHARGING/RECHARGING
For maximum battery life, we recommend the VECTOR® system be kept fully
charged at all times. If the battery is allowed to remain in a discharged state,
battery life will be shortened.
NOTE: Recharging battery after each use will prolong battery life; frequent
discharges between recharges will reduce battery life
IMPORTANT:
• MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING
• Charge unit for full 48 hours using AC method, prior to first use
• Recharge unit fully after each use
• Recharge unit once a month when not in use
9
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 10
3.1 110/120 VOLT AC CHARGING
1. Plug the barrel connector end of the AC/DC adapter into the small barrel
receptacle port on the jump-starter.
2. Plug the AC/DC adapter/charger into any standard 110/120 volt AC
wall outlet.
3. After initial 48 hour charge, charge this device for at least 24-30 hours or until
the green FULL indicator lights. Charge at least once a month when not in use.
4. When charging is complete and the FULL light lights, remove the AC/DC
charger plug and store in a safe place.
NOTE: The unit cannot be overcharged using the AC method. The VECTOR®
system also comes with a DC/DC charging adapter for recharging the
unit from a 12 volt DC accessory outlet in a vehicle or boat.
12 volt DC to DC method will NOT recharge the unit as effectively as
recharging from a 110/120 volt AC outlet. The 12 volt DC recharging
procedure is recommended only when it is necessary, as continued use of the
12 volt DC recharging procedure may shorten the battery system’s life.
If unit is fully discharged, it is recommended that the vehicle being used for
recharging be left running while the unit is being charged using the 12 volt DC
method.
WARNING:
Do not recharge for more than 3-4 hours maximum using 12 volt DC method.
3.2 12 VOLT DC CHARGING
1. Insert the plug that is marked “TO VEHICLE ACCESSORY OUTLET” of the
DC/DC charging adapter into the 12 volt DC accessory receptacle on the
vehicle or boat.
2. Insert the plug at the other end of this charging adapter marked “TO JUMP
STARTER OUTLET” into the recharging port on the front panel of the unit.
3. IN ORDER TO PROPERLY CHECK THE CHARGE LEVEL OF THE JUMP
STARTER BATTERY DURING DC CHARGING, DISCONNECT DC
ADAPTER FROM ACCESSORY OUTLET, PUSH BATTERY LEVEL STATUS
SWITCH AND OBSERVE CHARGE LEVEL. UNIT IS CHARGED WHEN
GREEN LED LIGHTS. DO NOT EXCEED 3-4 HOURS MAXIMUM.
3. When charging is completed, remove the power cord and store in a safe
place.
CAUTION: THIS PLUG USES AN 8 AMP FUSE. FOR CONTINUED
PROTECTION AGAINST RISK OF FIRE, REPLACE FUSE ONLY WITH
SAME TYPE AND RATING.
3.3 REPLACE FUSE
1. Remove plug from accessory outlet. Remove the gold cap by turning
counterclockwise and lifting off.
2. Remove center pin and spring.
3. Replace fuse with same type and size fuse (8 amp).
4. Replace center pin and spring inside plug.
5. Replace gold cap by turning clockwise onto plug.
10
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 11
3.4 ESTIMATED BATTERY LIFE
Table I shows the relationship of the frequency of use between recharging and
the expected number of discharge/recharge cycles.
Table I - Estimated Battery Life between recharges (lifetime of unit’s battery)
USE
RECHARGES
1000+
700+
1
5
10
500+
4. OPERATION AS A 12 VOLT DC PORTABLE POWER SUPPLY
1. Lift up the cover of the unit’s 12 volt DC accessory receptacle (See Figure 1).
2. Insert the 12 volt DC plug from the appliance into the receptacle on the unit.
3. Turn on the appliance, and operate as usual.
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT
DRAW MORE THAN 5 AMPS DC
Table II shows the estimated 12 volt DC operation time when using a fully
charged system.
Table II - VECTOR® as a 12 volt DC Power Supply
Appliance
Estimated Power Usage Operating Time
(Watts)
(hours)
Cell phone
1
120 (talk time)
Fluorescent light
4
40
24
14
10
2
Radio, fan, depth finder
Camcorder, VCR, spotlight
Power tools, bilge pump
Car vacuum
9
15
24
80
NOTE: ALL TIMES ARE APPROXIMATE AND BASED UPON A FULLY CHARGED UNIT.
5. EMERGENCY AREA LIGHT
The area light is controlled by an On/Off pushbutton. Make sure the lamp is turned
OFF when the unit is being recharged or stored. The light is efficient and will
operate up to 200 hours on a full charge. The area light’s operating life is 10,000
hours.
6. REPLACEMENT PARTS
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer
Service: 954-584-4446 or toll-free 866-584-5504.
6.1 BATTERY REPLACEMENT
It is recommended that the unit be returned to Vector Customer Service for
battery replacement: Contact 954-584-4446 or toll-free 866-584-5504.
WARNING:
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty
electrical tape to prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode
11
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 12
6.2 BATTERY DISPOSAL:
This unit contains a maintenance-free, non-spillable, sealed lead-
acid battery. This battery is fully recyclable and should be accepted
at any location that accepts common automotive starter batteries.
Examples of places that accept these batteries are: County or
municipal recycling drop-off centers, scrap metal dealers and
retailers who sell automotive replacement lead acid starter
batteries. For more information on recycling this battery, call toll-
free 877-288-7722.
7. SPECIFICATIONS
Model ..............................................................................VEC022
Boost Ampere ............................450 Instantaneous Cranking Amps
Battery Type ..............Sealed, high energy density, AGM, lead-acid,
........rechargeable, maintenance-free, 12 volt DC, 19 Amp-hour
Area Light ..............................................Light Emitting Diode (LED)
Booster Cables ..............................................Heavy duty cable with
..........................................................450 Amp copper clamps
Accessory Socket ............................Self-Resetting Breaker 5 Amps
DC Charging Adapter ....................................................12 volt DC
AC Charging Adapter 110/120 Volt AC (700mA, 12 Volt DC Output)
12
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 13
2-YEAR LIMITED WARRANTY
This limited warranty program is the only one that applies to this product, and it sets forth all the
responsibilities of Vector Products, Inc., regarding this product. There is no other warranty, other than
those described herein.
This Vector Products, Inc. product is warranted, to the original purchaser only, to be free of defects in
materials and workmanship for two years from the date of purchase without additional charge. The
warranty does not extend to subsequent purchasers or users. Vector Products, Inc. will not be responsible
for any amount of damage in excess of the retail purchase price of the product under any circumstances.
Incidental and consequential damages are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or damage
to units from misuse or incorrect installation. Misuse includes wiring or connecting to improper polarity
power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage
prepaid to Vector Products, Inc.. Any defective product, other than accessories, that is returned to Vector
Products, Inc. within 30 days of the date of purchase will be replaced free of charge. If such a product
is returned more than 30 days but less than two years from the purchase date, Vector Products, Inc. will
repair the unit or, at its option, replace it free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector Products, Inc.’s
option. A unit may be replaced with a new or reconditioned unit of the same or comparable design.
The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty
period. The customer is responsible for the shipping charges on all returned items after 30 days. During
the warranty period, Vector Products, Inc. will be responsible for the return shipping charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from
normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or
exposure to sunlight), accidents, damage during shipping to our service facility, alterations,
unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and
maintenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department toll free
866-584-5504 for general repair information and charges if applicable. You may also contact us
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser
specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Products, Inc. Technical
Support by telephone, fax or mail. We suggest that you keep the original packaging in case you need
to ship the unit. When returning a product, include your name, address, phone number, dated sales
receipt (or copy) and a description of the reason for return and product serial number. After repairing
or replacing the unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector Products, Inc..
Enter “VEC022” as Model and “Jump-Start System and 12VDC Power Supply” as Product Type. All
Vector Products, Inc. products must be registered within (30) days of purchase to activate this warranty.
Mail the completed registration form, along with a copy of the original sales receipt to:
ATTN.: CUSTOMER SERVICE / VECTOR PRODUCTS, INC.
4140 S.W. 30Ave., Ft. Lauderdale, FL 33312
TEL: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.
13
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 14
14
VEC022 Manual_Final_073106.qxp 7/31/06 6:36 PM Page 15
DS073106
|