Transition Networks Network Router TN CWDM SFP 1xx0 User Manual

User’s Guide  
TN-GLC-xx-xx and TN-CWDM-SFP-1xx0 Cisco  
CompatibleSmall Form Factor Pluggable (SFP)  
Transceiver Modules**  
The Transition Networks TN-GLC-xx-xx and TN-CWDM-  
SFP-1xx0 series small form factor pluggable (SFP) transceiver  
TN-GLC-T  
modules are designed to install in any SFP port, allowing for1000Base-T, 1000Base-SX  
or 1000Base-LX interfaces to the network through the SFP connector. The TN-GLC-xxx  
and TN-CWDM-SFP-1xx0 transceivers are designed for bi-directional serial-optical data  
communications such as Gigabit Ethernet or fiber channel at speeds up to 2.125 Gbps.  
TN-GLC-SX-MM  
Part Number Port Description  
TN-GLC-BX-0  
TN-CWDM-SFP-1xx0  
TN-GLC-T  
1000Base-T , RJ-45  
100m (328 ft)*  
TN-GLC-SX-MM  
1000Base-SX, duplex LC, 850 nm,  
220 m (722 ft)* on 62.5/125 µm fiber  
550 m (1840 ft)* on 50/125 µm fiber  
TN-GLC-SX-MM-2K 1000Base-SX, duplex LC 1300 nm, extended multimode  
up to 2 km (1.2 miles)*  
TN-GLC-LH-SM  
TN-GLC-BX-U  
TN-GLC-BX-D  
1000Base-LX, 1310 nm, single mode  
10 km (6.2 miles)*  
1000Base-BX, Simplex LC 1310 nm Tx/1490 nm Rx nm,  
single mode, single fiber 10 km (6.2 miles)*  
1000Base-BX, Simplex LC 1490 nm Tx/1310 nm Rx nm,  
single mode, single fiber 10 km (6.2 miles)*  
*Unless otherwise indicated, the distances listed are the typical maximum cable  
distance. The actual maximum cable distances are dependent upon the physical  
characteristics of the network installation.  
**Transition Networks' SFP modules fully comply with the Multi-Sourcing Agreement  
(MSA). This compliance allows our SFP modules to be used in other MSA compliant  
SFP platforms without problems. In  
Installation . . . . . . . . . . . . . . . . . . . . . . . . .3  
Cable Specifications . . . . . . . . . . . . . . . . .5  
Technical Specifications . . . . . . . . . . . . . .8  
Contact Us . . . . . . . . . . . . . . . . . . . . . . . . .9  
Compliance Information . . . . . . . . . . . . .11  
addition, TN SFP modules specified in  
this manual are also compatible with all  
Cisco SFP-based routers and switches, as  
well as its IOS software. TN SFP  
modules ARE NOT Cisco OEM brand  
modules.  
 
TN-GLC-xx-xx SFPs  
Installing the fiber cables  
Cable Specification  
Copper cable (Category 5 -- minimum requirement)  
1. Locate or build 1000Base-SX-compliant or 1000Base-LX-compliant fiber  
cable with male TX to RX connectors installed at both ends.  
Gauge = 24 to 22 AWG; Attenuation = 22.0 dB /100m @ 100 MHz  
• Straight-through OR crossover cable may be used.  
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used  
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a gigabit network.  
• Use only dedicated wire pairs for the active pins; e.g., blue/white &  
white/blue,  
2. Install the fiber cable as shown below.  
Connect fiber cable  
to media converter  
as shown.  
Connect fiber cable  
to other device  
(media converter,  
hub, etc.) as shown  
orange/white & white/orange, etc.  
• Do not use flat or silver satin wire.  
RX  
TX  
RX  
TX  
Straight-Through Cable  
Crossover Cable  
1
2
1
2
1
2
1
2
Twisted Pair #1  
Twisted Pair #2  
Twisted Pair #1  
Twisted Pair #2  
3
6
3
6
3
6
3
6
5
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
4
 
TN-GLC-xx-xx SFPs  
Fiber cable -- continued  
Fiber cable  
TN-GLC-FE-100FX  
TN-GLC-GE-100FX  
1300 nm multimode  
1300 nm multimode  
min: -23.5 dBm  
min: -32.0 dBm  
8.5 dB  
The physical characteristics must meet or exceed IEEE 802.3zspecifications.  
Singlemode fiber (recommended):  
Multimode fiber (recommended):  
Multimode fiber (optional):  
9 µm  
Fiber Optic Transmitter Power:  
max: -14.0 dBm  
max: -8.0 dBm  
62.5/125 µm  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
100/140, 85/140, 50/125 µm  
TN-GLC-SX-MM  
850 nm multimode  
TN-GLC-FE-100LX  
1310 nm single mode  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
min: -9.5 dBm  
min: -18.0 dBm  
8.5 dB  
max: -3.5 dBm  
max: -1.0 dBm  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
min: -15.0 dBm  
min: -34.0 dBm  
19.0 dB  
max: -8.0 dBm  
max: -0.0 dBm  
TN-GLC-SX-MM-2k  
1300 nm multimode  
min: -9.0 dBm  
min: -19.0 dBm  
18.0 dB  
TN-GLC-ZX-SM  
1550 nm single mode  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
max: -1.0dBm  
max: -1.0 dBm  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
min: 0.0 dBm  
min: -24.0 dBm  
24 dB  
max: +5.0 dBm  
max: -3.0 dBm  
TN-GLC-LH-SM  
1310 nm singlemode  
TN-CWDM-SFP-1xx0  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
1270nm -1610nm single mode  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
min: -9.5 dBm  
min: -20.0 dBm  
10.5 dB  
max: -3.0 dBm  
max: -3.0 dBm  
min: 0.0 dBm  
min: -25.0 dBm  
25 dB  
max: +5.0 dBm  
max: -3.0 dBm  
TN-GLC-BX-U  
1310 nm Tx/1490 nm Rx single mode  
1490 nm Tx/1310 nm Rx single mode  
min: -9.0 dBm  
min: -21.0 dBm  
12.0 dB  
For the most up-to-date information on the TN-GLC-xx-xx transceiver module, view  
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,  
Subchapter J applicable at the date of manufacture.  
TN-GLC-BX-D  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
max: -1.0 dBm  
max: -1.0 dBm  
WARNING: Visible and invisible laser radiation when open. Do not stare into beam  
or view directly with optical instruments. Failure to observe this warning could result  
damage to your eyes or blindness.  
WARNING: Use of controls, adjustments or the performance of procedures other than  
those specified herein could result in hazardous radiation exposure.  
TN-GLC-BX-U-40  
1310 nm Tx/1490 nm Rx single mode  
1490 nm Tx/1310 nm Rx single mode  
min: -3.0 dBm  
min: -23.0 dBm  
20.0 dB  
TN-GLC-BX-D-40  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
max: +2.0 dBm  
max: -1.0 dBm  
The fiber optic transmitters on this device meet Class I Laser safety requirements per  
IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.  
TN-GLC-BX-U-60  
1310 nm Tx/1490 nm Rx single mode  
1490 nm Tx/1310 nm Rx single mode  
min: -2.0 dBm  
min: -25.0 dBm  
23.0 dB  
TN-GLC-BX-D-60  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
max: +4.0 dBm  
max: -1.0 dBm  
TN-GLC-FE-100BX-U  
TN-GLC-FE-100BX-D  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
1310 nm Tx/1550 nm Rx single mode  
1550 nm Tx/1310 nm Rx single mode  
min: -14.0 dBm  
min: -32.0 dBm  
18.0 dB  
max: -8.0 dBm  
max: -0.0 dBm  
7
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
6
 
TN-GLC-xx-xx SFPs  
Technical Specification  
For use with Transition Networks Model TN-GLC-xxx or equivalent.  
Contact Us  
Technical support  
Technical support is available 24 hours a day.  
U.S.A. and Canada: 1-800-260-1312  
Standard:  
IEEE 802.3 2003; ANSI X3.297-1997  
TN-GLC-FE-xxx and TN-GLC-GE-xxx: Compiant with  
IEEE 802.3 100Base-Fx; IEEE802.3ah 100Base-Bx;  
Intermediate - Reach Sonet OC-3/SDH STM-1 (s-1-1)  
International:  
00-1-952-941-7600  
Transition now  
TN-GLC-xx-xx and TN-CWDM-SFP-1xx0 modules:  
IEEE 802.3z Gigabit Ethernet; FC-1x/2x SM-LC-L FC-PI.  
TN-GLC-T modules: Compliant with IEEE 802.32 Gigabit  
Ethernet (1000Base-T)  
Chat live via the Web with Transition Networks Technical Support.  
Compliant with  
Web-Based seminars  
Transition Networks provides seminars via live web-based training.  
Output wavelength  
Dimensions:  
-6.0 < λc < +7.5 nm  
0.52 x 2.18 x 0.33’’ (13.4 x 55.5 x 8.5 mm, Fiber)  
0.95 x 2.8 x 0.54” (14-0 x 71.1 13.7 mm, Copper)  
1 oz. (28 g) approximately  
E-Mail  
Ask a question anytime by sending an e-mail to our technical support staff.  
Weight:  
Power:  
3.3V, Fiber 0.66 W; Copper 1.0 W  
0°C to 70°C (32°F to 158° F )  
-40°C to 85°C (-40° to 185°F)  
5% to 95%, non-condensing  
0 to 10,000 feet  
Operating Temp:  
Storage Temp:  
Humidity:  
Altitude:  
Address  
Transition Networks  
10900 Red Circle Drive  
Minnetonka, MN 55343, U.S.A.  
telephone:  
toll free:  
fax:  
952-941-7600  
800-526-9267  
952-941-2322  
Warranty:  
Lifetime  
Note: Transition Networks' SFP modules fully comply with the Multi-Sourcing  
Agreement (MSA). This compliance allows our SFP modules to be used in  
other MSA compliant SFP platforms without problems. In addition, TN SFP  
modules are also compatible with all Cisco SFP-based routers and switches, as  
well as its IOS software and SMARTnet. TN SFP modules ARE NOT Cisco  
OEM brand modules.  
9
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
8
 
TN-GLC-xx-xx SFPs  
Compliance Information  
Declaration of Conformity  
CE Mark: IEC-60825; FDA 21; CFR 1040.10 and 1040.11  
Name of Mfg:  
Transition Networks  
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.  
TN-GLC-xx-xx Series Transceiver Modules  
TN-GLC-T, TN-GLC-SX-MM, N-GLC-SX-MM-2k,  
TN-GLC-LH-SM, TN-GLC-BX-U, TN-GLC-BX-D,  
TN-GLC-BX-U-40, TN-GLC-BX-D-40, TN-GLC-BX-U-60,  
TN-GLC-BX-D-60, TN-GLC-FE-100BX-U,  
TN-GLC-FE-100BX-D, TN-GLC-FE-100FX,  
TN-GLC-FE-100LX, TN-GLC-GE-100LX, TN-GLC-ZX-SM,  
TN-CWDM-SFP-1xx0  
FCC regulations  
Model:  
Part Number(s):  
This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference, in which  
case the user will be required to correct the interference at the user's own expense.  
Canadian regulations  
Regulation:  
Purpose:  
EMC Directive 89/336/EEC  
To declare that the TN-GLC-xxx to which this declaration refers  
is in conformity with the following standards:  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out  
on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites  
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage  
radioélectrique édicté par le ministère des Communications du Canada.  
IEC 60825-1; IEC60825-2; FC1X/2X SM-LC-L FC-PI; IEEE 802.3z 2003; ANSI X3.297  
1997; Class A; FDA 21; CFR1040.10; CFR1040.11  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive(s) and Standard(s).  
October 2008____  
European regulations  
Warning  
Stephen Anderson, Vice-President of Engineering  
Date  
This is a Class A product. In a domestic environment this product may cause radio interference in  
which case the user may be required to take adequate measures.  
Achtung !  
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses  
Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen  
verantwortlich.  
Attention !  
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des  
interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques  
appropriées.  
In accordance with European Union Directive 2002/96/EC of the European Parliament  
and of the Council of 27 January 2003, Transition Networks will accept post usage  
returns of this product for proper disposal. The contact information for this activity can  
be found in the 'Contact Us' portion of this document.  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in  
damage to the public telephone network.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-  
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über  
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  
Konformität.  
11  
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)  
[email protected] -- Click the Transition Now link for a live Web chat.  
10  
 
TN-GLC-xx-xx SFPs  
Trademark notice  
All trademarks and registered trademarks are the property of their respective owners.  
Copyright restrictions © 2004 Transition Networks. All rights reserved. No part of this work may  
be reproduced or used in any form or means (graphic, electronic, mechanical) without written  
permission from Transition Networks.  
Printed in the U.S.A. 33389.D  
12  
 

Teledyne Oxygen Equipment 318R User Manual
Trilogy Touch Technology Cell Phone 500 19 54 User Manual
Tripp Lite Network Cables N201 001 RD User Manual
Tyan Computer Computer Monitor tgm 200 User Manual
Uniden Scanner UBC93XLT User Manual
Uniden Two Way Radio UH044DP User Manual
Universal Indoor Furnishings HS 303 User Manual
VistaQuest Digital Camera VQ5325 User Manual
VTech Cordless Telephone t2415 User Manual
VTech Telephone 5831 User Manual