Toshiba Digital Camera IK 53N User Manual

OPERATING GUIDE  
CCD CAMERA  
IK-53N/IK-52N  
FCC Statement  
This device com plies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) This device m ay not cause harm ful interference, and (2) this device m ust ac-  
cept any interference received, including interference that m ay cause undesired operation.  
INFORMATION  
This equipm ent has been tested and found to com ply with the lim its for a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These lim its are designed to provide reasonable protection  
against harm ful interference when the equipm ent is operated in a com m ercial environm ent.  
This equipm ent generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction m anual, m ay cause harm ful interference to radio  
com m unications. Operation of this equipm ent in a residential area is likely to cause harm ful  
interference in which case the user will be required to correct the interference at his own ex-  
pense.  
USER-INSTALLER CAUTION: Your authority to operate this FCC verified equipm ent could be  
voided if you make changes or modifications not expressly approved by the party responsible for  
com pliance to Part 15 of the FCC rules.  
This Class A digital apparatus com plies with Canadian ICES-003.  
Cet appareil num érique de la classe A est com form e à la norm e NMB-003 du Canada.  
 
1.GENERAL  
The IK-53N/IK-52N is a m onochrom e video cam era using a solid im age sensor CCD (Charged  
Coupled Device).  
High Picture Quality  
The 410,000 pixels CCD provides a fine picture.  
Various Modes Setting  
The following m odes can be set by the switches on the rear panel.  
• Gain: Fixed/m anual adjustm ent (0 to +18 dB)  
• Field accum ulation/Fram e accum ulation  
Synchronized input/output (HD/VD)  
• 75term inal (at external synchronous input)  
Shutter function: Norm al/external trigger shutter  
Shutter speed  
External Synchronization  
External HD/VD signals are analyzed and the synchronization m ode is autom atically selected  
to m atch the input signals.  
Internal Synchronizing Signal Output  
HD and VD signals can be outputted from the 12-pin connector by changing the switch posi-  
tion on the rear panel.  
Electric Shutter Speed  
A variety of shutter speeds (1/100 to 1/100,000 sec) is provided to perm it choice suitable for  
shooting conditions.  
External Trigger Function  
A trigger input provides one still im age. This function exactly captures a subject m oving at a  
high speed.  
Cabinet Fixing  
The cabinet fixing screw hole is provided below the front panel which includes the CCD datum  
level. Fix the cam era using this screw hole to m inim ize shifts in the optical axis.  
2
 
2.CAMERA PARTS AND FUNCTIONS  
Top/Bottom/Front Side  
2
1
1
2
Lens m ount (C m ount)  
This is used to m ount a C-m ount type lens or  
optical equipm ent.  
Cam era fixing reference hole (top side)  
[Top]  
3
3
4
Cam era fixing reference hole/Tripod fixing m etal  
screw hole (bottom side)  
Cam era fixing reference hole/Tripod fixing m etal  
screw hole (bottom side)  
NOTE  
When the m ass of lens exceeds 300g, fix the cam -  
era at the side of the lens.  
[Bottom]  
4
5
5
Im aging area  
The protection cap is attached on the lens m ount  
portion. After rem oving the cap, m ount the lens.  
Be careful not to scratch or touch the optical  
area.  
[Front]  
3
 
Rear Side  
4
1
2
3
4
5
6
7
8
9
0
O
N
2
3
4
5
1
2
HD/VD  
EXT  
75  
INT  
ON  
OFF  
SHT  
Enlarged  
TRG  
FRM  
M.G  
MIN  
MAX  
1
3
4
5
VIDEO OUT  
DC IN/SYNC  
M GAIN  
1
VIDEO OUT DC IN/SYNC plug (12-pin connector)  
This receives +12 VDC, and sends a video signal from the cam era. When a synchronizing signal  
generator is connected to this plug and an external synchronizing signal (HD/VD signal) is applied,  
the cam era can be operated synchronously with the external signal.  
2
3
75term inal switch (Term inal of external synchronizing HD/VD input signal)  
Set this switch to OFF when not term inated. The factory setting is ON.  
HD/VD signal input/output selector switch  
Set to INT to output the HD/VD signals from the cam era, and EXT to input external HD/VD signals.  
The factory setting is EXT.  
4
MODE SELECT switch  
1
Shutter speed setting (MODE SELECT switch bit 1 to 4)  
Set to the shutter speed suitable for the shooting conditions. For each setting position, refer to  
P. 7. The factory setting position is shutter OFF.  
2
3
Reset restart/External trigger m ode setting (MODE SELECT switch bit 5 to 7)  
For each setting position, refer to P. 8 to 13. The factory setting position is NORMAL.  
Trigger polarity setting (MODE SELECT switch bit 8)  
Selects the polarity of an externally inputted trigger.  
OFF: Positive ON: Negative  
The factory setting position is OFF.  
4
5
Field accum ulation/Fram e accum ulation setting (MODE SELECT switch bit 9)  
For the m ode setting, refer to P. 6. The factory setting position is Field accum ulation.  
Gain selector switch setting (MODE SELECT switch bit 0)  
This switch selects the m odes OFF (fixed) or ON (m anual). The factory setting is OFF (fixed).  
5
Manual gain (M GAIN) control knob  
This adjusts the gain of a video signal when the gain m ode is set to ON by the MODE SELECT  
5
switch bit 0 on step . The factory setting is the fully counterclockwise position.  
4
 
3.CONNECTIONS  
Standard Connection  
Image processor  
Lens  
Camera Cable  
(optional)  
IK-53N  
IK-52N  
Cautions on Connection  
• When connecting the cam era cables, be sure to turn off the cam era and the other equipm ent  
connected.  
• When using another lens, the best cam era perform ance of this cam era m ay not be obtained.  
(For exam ple, low resolution m ay occur, and flare, ghost or shading m ay occur)  
• Use the DC power source described below.  
• Power supply voltage: +10.5V to +15V  
• Current rating: More than 830 m A  
• Ripple voltage: Less than 50 m V(pp)  
Connector Pin Assignments  
1
9
10  
2
8
Connector:  
HR10A–10R–12PB by HIROSE electronics Co. Ltd  
11 12  
7
3
4
6
5
Pin External synchroniza-  
No. tion mode (HD/VD)  
Internal synchroniza-  
tion output signal  
GND  
Reset restart  
GND  
DC+12V  
External trigger mode  
1
2
3
4
5
6
7
8
9
GND  
GND  
DC+12V  
DC+12V  
DC+12V  
Video output (GND) Video output (GND)  
Video output (GND)  
Video output (GND)  
Video output (signal) Video output (signal) Video output (signal) Video output (signal)  
HD input (GND)  
HD input (signal)  
VD input (signal)  
GND  
HD input (GND)  
HD input (signal)  
Reset (signal)  
GND  
HD input (GND)  
HD input (signal)  
VD input (signal)  
GND  
HD output (GND)  
HD output (signal)  
VD output (signal)  
GND  
VIDEO INDEX output VIDEO INDEX output  
10  
(signal)  
(signal)  
Trigger pulse input  
(signal)  
11  
12 VD input (GND)  
Reset (GND)  
VD input (GND)  
VD output (GND)  
5
 
4.SETTING  
4-1. Field accumulation/Frame accumulation  
This switch selects the potential accum ulation m ode of the CCD output signal. The m ode can  
be set with the MODE SELECT switch bit 9 on the rear panel.  
Rear  
MODE SELECT Switch  
HD/VD  
EXT  
75  
1
2
3
4
5
6
7
8
9
0
O
N
INT  
ON  
OFF  
SHT  
TRG  
FRM  
M.G  
Field accumulation Frame accumulation  
9
9
MIN  
MAX  
VIDEO OUT  
DC IN/SYNC  
M GAIN  
6
 
4-2. Electronic Shutter  
This can be set with the MODE SELECT switch located on the rear panel.  
Description of the MODE SELECT Switch  
Rear  
MODE SELECT Switch  
HD/VD  
EXT  
Bits 1 to 4 : Shutter speed selection*  
75Ω  
1
2
3
4
5
6
7
8
9
0
O
N
INT  
Bits 5 to 7 : External trigger mode selection  
Bit 8 : Trigger polarity selection (Positive/Negative)  
Bit 9 : Field accumulation/Frame accumulation  
Bit 0 : Gain selection (OFF/ON)  
ON  
OFF  
SHT  
TRG  
FRM  
M.G  
MIN  
MAX  
VIDEO OUT  
DC IN/SYNC  
M GAIN  
*The electronic shutter cannot be used in the reset-restart operation.  
Normal Shutter  
This m ode perm its a high-speed m oving subject to be captured clearly with a shutter function  
incorporating a continuously available video signal. Set bit 5 of the MODE SELECT switch to  
OFF (i.e., the left side) as illustrated in the table below.  
Reset restart  
Normal  
shutter  
or  
external trigger mode  
5
5
(unitsecond)  
OFF  
1/100  
1/250  
1/500  
1/1000  
1/2000  
1
2
3
4
5
6
7
8
9
0
1
1
1
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
2
3
4
5
6
7
8
9
0
2
3
4
5
6
7
8
9
0
2
3
4
5
6
7
8
9
0
1/4000  
1/10000  
1/50000 1/100000  
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
7
 
4-3. Reset Restart  
Input of an external reset-restart signal (VD) perm its one screen of inform ation to be output at  
an arbitrary tim ing. To set this m ode, set the external trigger m ode selection switch (i.e., MODE  
SELECT switch bits 5, 6, and 7) as illustrated in the diagram below.  
MODE SELECT Switch  
Rear  
HD/VD  
EXT  
75Ω  
1
2
3
4
5
6
7
8
9
0
O
N
INT  
ON  
OFF  
SHT  
TRG  
FRM  
M.G  
Reset restart  
5
6
7
MIN  
MAX  
VIDEO OUT  
DC IN/SYNC  
M GAIN  
Long Term Exposure  
When the cam era is used and sufficient sensitivity cannot be obtained for the reset-restart  
function under norm al operating conditions, or when observation of the trail of a m oving  
subject is desired, the exposure tim e can be extended to allow high-sensitivity im ages to be  
obtained. To achieve this, please input from an external source a VD signal that has an ex-  
panded VD pulse and VD pulse interval.  
Input Tim ing Chart Exam ple  
External HD IN  
External VD IN  
V reset  
V reset  
About 1H  
About 1H  
(Internal VD)  
Exposure period  
Exposure period  
Exposure period  
VIDEO OUT  
VIDEO INDEX  
1V  
1V  
External VD interval: more than 1V  
8
 
4-4. External Trigger Mode  
Input of an external trigger perm its a high-speed m oving object to be captured at the proper  
position. Set the rear panel external trigger m ode selection switch (i.e., MODE SELECT switch  
bits 5, 6, and 7) as illustrated in the diagram below.  
MODE SELECT Switch  
REAR  
HD/VD  
EXT  
75  
1
2
3
4
5
6
7
8
9
0
O
N
INT  
ON  
OFF  
SYNC-NONRESET  
SYNC-RESET  
SHT  
5
6
7
5
6
7
TRG  
FRM  
M.G  
MIN  
MAX  
VIDEO OUT  
DC IN/SYNC  
NOTE  
M GAIN  
In the external trigger m ode, the  
cam era is autom atically set to Field  
a ccu m u la tio n re g a rd le s s o f th e  
MODE SELECT switch bit 9 position.  
The following two m odes are available for video tim ing.  
SYNC-NON RESET Mode  
In this m ode, the video is synchronized to VD after the trigger input.  
When external HD*/VD is input: Sync is to external VD  
When external HD*/VD is not input: Sync is to internal VD  
*There is autom atic determ ination of external sync or internal sync by the presence or  
absence of external HD input.  
SYNC-RESET Mode  
In this m ode, reset is applied to the internal VD and the video is output after a fixed period  
following the trigger pulse.  
External Trigger Shutter Speed Setting  
The following two m ethods are available for shutter speed setting.  
1 pulse trigger mode (Setting by the MODE SELECT switch of the rear panel)  
For shutter speed, refer to the table below.  
(unitsecond)  
1/100  
1/250  
1/500  
1/1000  
1/2000  
1
1
1
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
2
3
4
5
6
7
8
9
0
2
3
4
5
6
7
8
9
0
2
3
4
5
6
7
8
9
0
1/4000  
1/10000  
1/50000 1/100000  
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
9
 
Pulse Width Trigger Mode (Setting by Trigger Pulse Width)  
Set all dip switches (1 to 4) of the rear panel to “OFF”.  
An arbitrary shutter speed is obtained by setting the width of the trigger pulse to 2 µs or  
greater.  
Shutter speed = Trigger pulse width + 97 µ sec  
1
2
3
4
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1.7 µs  
About 98.7 µs  
Exposure period*2  
Exposure period*2  
VD OUT*3  
VIDEO INDEX  
Video output  
262.5H  
*1: Externally input signal  
*2: Exposure tim e = Trigger pulse width + 97 µs  
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)  
*3: As long as there is no external sync input, the internal VD will be output when the rear  
panel HD/VD signal input/output switch is set to the INT side.  
*4: Video is output at the falling edge of the internal VD following com pletion of the exposure  
period.  
The video and the VIDEO INDEX have a paired relationship.  
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
10  
 
Pulse Width Trigger SYNC-NON RESET Picture Output Timing  
(At Time of One-shot or Continuous External VD/Continuous External HD Input)  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1.7 µs  
About 98.7 µs  
Exposure period*2  
Exposure period*2  
ExternalHD IN*1  
ExternalVD IN*1  
About 1H  
(InternalVD)  
VIDEO INDEX  
Video output  
262.5H  
The internal VD falling edge is within the exposure  
3
*
period and thus video is not output.  
*1: Externally input signal  
*2: Exposure tim e = Trigger pulse width + 97 µs  
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)  
*3: Video is output at the falling edge of the internal VD following com pletion of the exposure  
period.  
The video and the VIDEO INDEX have a paired relationship.  
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
1 Pulse Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1.7 µs  
2
Exposure period  
*
2
Exposure period  
*
VD OUT*3  
VIDEO INDEX  
Video output  
262.5H  
*1: Externally input signal  
*2: Exposure tim e is determ ined by the setting of the MODE SELECT switch. Refer to page 9.  
As long as there is no external sync input, the internal VD will be output when the rear  
panel HD/VD signal input/output switch is set to the INT side.  
*3: Video is output at the falling edge of the internal VD following com pletion of the exposure  
period.  
The video and the VIDEO INDEX have a paired relationship.  
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
11  
 
1 Pulse Trigger SYNC-NON RESET Picture Output Timing  
(At Time of One-shot or Continuous External VD/Continuous External HD Input)  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1.7 µs  
Exposure period*2  
Exposure period*2  
External HD IN*1  
External VD IN*1  
About 1H  
(Internal VD)  
VIDEO INDEX  
Video output  
262.5H  
The internal VD falling edge is within the exposure  
3
*
period and thus video is not output.  
*1: Externally input signal  
*2: Exposure tim e is determ ined by the setting of the MODE SELECT switch. Refer to page 9.  
*3: Video is output at the falling edge of the internal VD following com pletion of the exposure  
period.  
The video and the VIDEO INDEX have a paired relationship.  
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
1 Pulse Width Trigger SYNC-RESET Picture Output Timing  
Negative polarity mode  
Trigger*1  
Positive polarity mode  
About 1.7µs  
About 98.7µs  
Exposure period*2  
Exposure completion  
to 1H  
3
*
VD OUT  
Video output  
VIDEO INDEX  
262.5H  
*1: Externally input signal  
*2: Exposure tim e = Trigger pulse width + 97 µs  
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)  
*3: VD is generated after 0 to 1H following the com pletion of the exposure period and the  
video is synchronized to this and output.  
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
12  
 
1 Pulse Trigger SYNC-RESET Picture Output Timing  
Negative polarity mode  
Positive polarity mode  
Trigger*1  
About 1.7 µs  
Exposure period*2  
Exposure completion  
to 1H*3  
VD OUT  
Video output  
VIDEO INDEX  
262.5H  
*1: Externally input signal  
*2: Exposure tim e is determ ined by the setting of the MODE SELECT switch. Refer to page 9.  
*3: VD is generated after 0 to 1H following the com pletion of the exposure period and the  
video is synchronized to this and output.  
NOTE  
When the next trigger is input before com pletion of the output of the video corresponding to  
the trigger, there will be an effect on the video.  
External Sync Operation  
Shutter mode  
At tim e of SYNC-NON  
RESET m ode  
HD input VD input  
Note  
Internal sync m ode  
N
Y
N
Y
External sync m ode  
Only V reset is applied due to VD input.  
Norm ally not used.  
N
Y
HD is synchronized to external, but  
video is not output because there is no  
VD input. Norm ally not used.  
Y
N
At tim e of SYNC-RESET  
m ode  
Internal sync m ode. The presence of VD  
is ignored, and after a specified tim e  
after a trigger input, V reset is applied.  
N
Y
HD is synchronized to external. The pres-  
ence of VD is ignored, and after a specified  
tim e after a trigger input, V reset is applied.  
At tim e of reset restart  
HD is synchronized to external. Video is  
output due to VD input.  
Y
N
Y
Y
N
HD is synchronized to the inside of the  
cam era. Video is output due to VD input.  
Video is not output because there is no  
VD input. Norm ally not used.  
At tim e of norm al shutter  
N
Y
N
Y
Internal sync m ode  
External sync m ode  
H
D is synchronized to external. Norm ally  
Y
N
N
Y
not used.  
Disabled  
Either Y or N is perm itted.  
13  
 
5.Input Output Signal Specifications  
HD Input Specifications  
HD/VD Output Amplitude Specifications  
4.5V  
HD  
2.0 to 5.0Vp-p  
0V  
4.0 µs to 10.0 µs  
VD  
4.5V  
* Input im pedance: 75or 10kor greater  
* Input am plitude 2.0 to 5.0 Vp-p (75term ina-  
tion ON or OFF)  
0V  
* Voltage and pulse width were m easured at pin  
6 of the 12-pin connector located on the rear  
panel.  
The am plitude level is the representative value  
when term inated with 10k. Output is enabled  
when the rear panel HD/VD signal input/output  
switch is set to the INT side.  
Trigger Pulse Specifications  
VIDEO INDEX Output Specifications  
2 to 5.0V  
4.5V  
0 to 0.4V  
(Positive polaritym ode)  
0V  
More than 2µs  
262.5H  
2 to 5.0V  
0 to 0.4V  
The am plitude level is the representative value  
when term inated with 10k.  
(Negative polaritym ode)  
More than 2µs  
VD Input Specifications  
* Input im pedance: 10kor greater  
* Voltage and pulse width were m easured at  
pin 11 of the 12-pin connector located on the  
rear panel.  
2.0 to 5.0Vp-p  
5H to 21H  
* Input im pedance: 75or 1kor greater  
* Input am plitude 2.0 to 5.0 Vp-p (75term ina-  
tion ON or OFF)  
* Voltage and pulse width were m easured at  
pin 7 of the 12-pin connector located on the  
rear panel.  
14  
 
External HD/VD Input Phase Specifications  
HD input  
clk=69.84ns  
100 clk  
100 clk  
VD input  
(ODD)  
Input the VD falling  
within this range.  
Camera VD  
(internal)  
455 clk  
455 clk  
HD input  
clk=69.84ns  
100 clk  
100 clk  
VD input  
(EVEN)  
Input the VD falling  
within this range.  
Camera VD  
(internal)  
The phase relationship of the external HD and VD should correspond to the center  
phase (i.e., the external HD falling edge) as illustrated in the above diagram .  
Allowable frequency deviation of external sync: 15.734 kHz ± 1%  
( ± 1% of horizontal sync frequency)  
External VD falling edge:  
Please input within about 100 clock cycles of the standard center phase.  
Note that V sync of the video is output with a delay of about 1H from the external  
VD at the tim e of reset-restart and the external trigger m ode.  
In the normal mode:  
Continuously with the HD period of 63.56 µs and VD period of 16.68 m s.  
Phase tim ing is as illustrated in the above diagram (with only the falling edge  
applicable).  
In the reset-restart/external trigger mode:  
Continuously with the HD period of 63.56 µs. VD (reset) is at an arbitrary tim ing  
with the phase of HD being within the standard of the above diagram .  
15  
 
6.CCD Output Waveform Timing Chart  
Horizontal Output Waveform Timing Chart  
HD  
91clk  
(6.36µs)  
3clk  
1clk  
40clk  
77clk  
22clk  
15clk  
752clk  
CCD  
output signal  
Total effective pixels 768clk  
Optical black  
portion  
Dummy  
pixels  
Optical black  
portion  
Horizontal transfer  
stop interval  
69.8ns  
Output video interval  
Horizontal blanking interval (11.0µs)  
Video  
output signal  
(Representative  
values)  
21clk HSYNC  
(1.47µs) 70clk  
(4.89µs)  
63clk  
(4.40µs)  
752clk  
(52.5µs)  
One horizontal scan interval (1H)  
910clk (63.56µs)  
16  
 
Vertical Output Waveform Timing Chart (2:1 Interlace Field Accumulation)  
Odd field (262.5H)  
Even field (262.5H)  
VD  
HD  
9H  
253.5H  
9H  
253.5H  
CCD  
output signal  
1
8
6
4
242.5  
1
8
6
3.5  
242.5  
Optical black Dry  
portion transfer  
Optical black  
portion  
Optical black Dry  
portion transfer  
Optical black  
portion  
Camera video  
output signal  
Vertical blanking interval  
(20H)  
Vertical blanking interval  
(20H)  
Vertical Output Waveform Timing Chart (2:1 Interlace Frame Accumulation)  
Odd field (262.5H)  
Even field (262.5H)  
VD  
HD  
9H  
253.5H  
9H  
253.5H  
CCD  
output signal  
1
8
6
4
242.5  
2
8
6
3.5  
242.5  
Optical black Dry  
portion transfer  
Optical black  
portion  
Optical black Dry  
Optical black  
portion  
portion  
transfer  
Camera video  
output signal  
Vertical blanking interval  
(20H)  
Vertical blanking interval  
(20H)  
17  
 
7.EXTERIOR VIEW  
IK-53N  
2-M2 depth 2.5 [0.10"]  
R0.3 (whole circumference)  
Dimensions: mm [inch]  
R0.3 (whole circumference)  
8.2 [0.32"]  
0.7 [0.03"]  
INT  
14.5 [0.57"]  
8.8 [0.35"]  
12.5 [0.49"]  
29 [1.14"]  
3 [0.12"]  
7.9 [0.31"]  
29 [1.14"]  
11.6 [0.06"]  
HD/VD  
EXT  
75  
ON  
OFF  
SHT  
TRG  
FRM  
M.G  
MIN  
MAX  
VIDEO OUT  
DC IN/SYNC  
M
GAIN  
3.8 [0.15]  
14.8 [0.58"]  
23.7 0.1 [0.93"]  
22 0.1 [0.87"]  
(16.5 [0.65"])  
3-M3 depth 3 [0.12"]  
4-M2 depth 3 [0.12"]  
IK-52N  
2-M2 depth 2.5 [0.10"]  
Dimensions: mm [inch]  
R0.3 (whole circumference)  
R0.3 (whole circumference)  
8.2 [0.32"]  
8.8 [0.35"]  
14.5 [0.57"]  
12.5 [0.49"]  
29 [1.14"]  
3 [0.12"]  
7.9 [0.31"]  
0.7 [0.03"]  
29 [1.14"]  
11.6 [0.06"]  
HD/VD  
EXT  
75Ω  
INT  
ON  
OFF  
SHT  
TRG  
FRM  
M.G  
MIN  
MAX  
VIDEO OUT  
DC IN/SYNC  
M
GAIN  
3.8 [0.15]  
14.8 [0.58"] 23.7 0.1 [0.93"]  
22 0.1 [0.87"]  
(16.5 [0.65"])  
3-M3 depth 3 [0.12"]  
4-M2 depth 3 [0.12"]  
18  
 
8.SPECIFICATIONS  
Power supply  
DC12V (Range +10.5 to +15V)  
Power consum ption  
Im age sensor  
IK-53N: 85m A (DC+12V), IK-52N: 90m A (DC+12V)  
IK-53N: Interline transfer 1/3 inch CCD  
IK-52N: Interline transfer 1/2 inch CCD  
Effective pixels  
768 x 494 (H/V)  
Effective shooting  
area  
IK-53N: 4.88 x 3.66m m  
IK-52N: 6.45 x 4.84m m  
Scan frequency  
H: 15.734 kHz, V: 59.94Hz  
Synchronizing sys-  
tem  
Internal/external (HD/VD) (HD/VD input/output area  
selected by the switch on the rear panel.)  
Allowable frequency  
deviation of external  
sync  
±1% (For horizontal frequency)  
Mode  
Field accum ulation  
Fram e accum ulation  
1 pulse trigger sync-reset  
Pulse width trigger sync-reset  
1 pulse trigger sync-nonreset  
Pulse width trigger sync-nonreset  
Reset restart  
Electronic shutter  
OFF , 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000,  
1/10000, 1/50000, 1/100000  
Gain switch  
Horizontal resolution  
OFF (0dB) / ON (0 to +18dB)  
570TV lines  
Standard subject  
illum inance  
IK-53N: 200 lx, IK-52N: 160 lx  
F5.6 (Gain: OFF)  
Minim um subject  
illum inance  
IK-53N: 0.5 lx, IK-52N: 0.4 lx  
F1.4 (when the m anual gain adjustm ent is at m axim um )  
S/N ratio  
60 dB  
Video output  
Output im pedance  
Infrared cut filter  
Dum m y glass  
Lens m ount  
1.0V(p-p)  
75unbalanced  
No  
Yes  
C m ount  
Operation ensuring  
0˚C to +40˚C/ 90% or lower  
tem perature/hum idity  
Vibration resistance/  
shock resistance  
Vibration resistance 70 m /S2 (10 to 200 Hz),  
Shock resistance 700 m /S2  
Weight  
45g  
External dim ension  
29 (W) x 29 (H) x 29 (D) m m (except for protruded  
portion)  
19  
 
Spectral Sensitivity Characteristics (Representative Values)  
(Including lens characteristics, excluding light source characteristics)  
IK-53N  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
400  
500  
600  
700  
800  
900  
1000  
Wave length (nm)  
IK-52N  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
400  
500  
600  
700  
800  
900  
1000  
Wave length (nm)  
20  
 
 

Toro Grill Accessory 252 Series User Manual
Toshiba Cash Register MA 305 User Manual
Toshiba Digital Camera PDR M61 User Manual
Toyota Automobile Matrix 2006 User Manual
TRENDnet Bluetooth Headset BlueSoleil User Manual
Tripp Lite TV Cables p945 06i User Manual
Tyco Network Card Escort 4580 User Manual
Uniden Cordless Telephone ANA 9500 User Manual
Vermont Casting Indoor Fireplace DVRT41 User Manual
Wagner SprayTech Paint Sprayer AC 4600 Professional User Manual