254/ 264 Series
Plastic Valves
V A L V E S
Extremely rugged residential/commercial valves designed for reliable
performance.
20 and 25mm (3⁄4" and 1") Electric Models
Features
254-06-04
254-16-04
• Male-threaded inlet and male-threaded or barbed outlet available
• Barbed insert models for use with poly pipe
• Manual flow control: adjustable to zero flow (254 Series)
• Manual bleed screw
264-16-04
264-06-03
264-06-04
Effluent flow-control
knob available
(Part No. 89-7855)
• Energy-efficient solenoid
• 45cm (18") lead wires for easy-access installation
• Self-cleaning, stainless-steel metering pin (electric models)
Manual bleed screw
Optional
flow control
• Stainless-steel diaphragm differential spring for smooth, positive
closing
• Single-piece rubber diaphragm for reliable, leak-free valve closing
• Tough, glass-filled Zytel® cap and body provides stability under
pressure
Tough, glass-
filled Zytel cap
and body
• Zytel Super Tough and stainless-steel construction for exceptional
durability
Single-piece rubber
diaphragm
• Available with or without flow control
Specifications
Stainless-steel
metering pin
25mm (1") Models
• Recommended flow range: 19-170 LPM (5-45 GPM)
• Operating pressure: 1.4-10 Bar (20-150 PSI)
• Burst pressure safety rating: 52 Bar (750 PSI)
254 Male x Male Valve
• Body styles: Globe valve
• 2X4-06: 25mm (1") male-threaded inlet and outlet
254 / 264 Series Friction Loss Chart – Metric Data (Bar)*
• 2X4-16: 25mm (1") male-threaded inlet, 25mm (1") insert
(barbed) outlet
Flow (LPM)
2
25
<0,1 0,1 0,4 0,7
0,1 0,2 0,2 0,3 0,4
50
75 100 125
20mm (3⁄4") Electric
25mm (1") Electric
• Solenoid: 50/60 Hz (24 V.a.c.)
• Inrush: 0.30 Amps, 7.20 VA
• Holding: 0.20 Amps, 4.80 VA
*Values are listed in Bar. For kPa values, multiply tabular values by
100. For Kg/cm2 values, multiply tabular values by 1,02. Flow rates
are recommended not to exceed 0,35 Bar loss
• Dimensions:
• 254 Series (with flow control):
152 x 115mm (H x W) (6" x 41⁄2") (H x W)
254 / 264 Series Friction Loss Chart – English Data (PSI)
• 264 Series (without flow control):
115 x 115mm (H x W) (41⁄2" x 41⁄2") (H x W)
Flow (GPM) 0.5
1
3
5
10 15
20 25
30
3
⁄4" Electric <1.0 <1.0 <1.0 1.5 3.0 6.5
20mm (3⁄4") Models
1" Electric
2.0 2.0 2.3 3.1 4.0 5.4
• Recommended flow range: 2-57 LPM (0.5-15.0 GPM)
• Operating pressure: 1-10 Bar (15-150 PSI)
• Burst pressure safety rating: 52 Bar (750 PSI)
Note: For optimum sprinkler performance when designing a system,
calculate total friction loss to ensure sufficient downstream pressure.
Flow rates are recommended not to exceed 5 PSI loss.
Specifying Information
• Body style: Globe valve
• 20mm (3⁄4") male-threaded inlet and outlet
2X4 X6 0X
• Solenoid: 50/60 Hz (24 V.a.c.)
• Inrush: 0.25 Amps, 6.00 VA
Flow Control Body Threads
Size
5–w/ F.C.
0–Male Thread x Male Thread-NPT 3–20mm (3⁄4")
6–w/o F.C. 1–Male Thread x Barb-NPT
For Example:
4–25mm (1")
• Holding: 0.19 Amps, 4.50 VA
When specifying a 25mm (1") electric 264 Series valve
without flow control and with a male thread x 25mm (1") insert,
you would specify:
• Dimensions:
76 x 102mm (H x W) (3" x 4" H x W)
264-16-04
3
4
20mm ( ⁄ ") available with male x male thread without flow control only.
|